| Throughput per
hour, native (uncompressed): |
T9840B (64
drives, 19 MB/sec) – 4.4 TB/hr
T9840C (64 drives, 30 MB/sec) – 6.9 TB/hr
T9940B (64 drives, 30 MB/sec) – 6.9 TB/hr
LTO Gen 2 (64 drives, 30–35 MB/sec) – up to 8.1 TB/hr
LTO Gen 3 (64 drives, 80 MB/sec) – up to 18.4 TB/hr
SDLT 600 (64 drives, 36 MB/sec) – 8.3 TB/hr
|
T9840B (2,048
drives, 19 MB/sec) – 140 TB/hr
T9840C (2,048 drives, 30 MB/sec) – 221 TB/hr
T9940B (2,048 drives, 30 MB/sec) – 221 TB/hr
LTO Gen 2 (2,048 drives, 30–35 MB/sec) – up to 258 TB/hr
LTO Gen 3 (2,048 drives, 80 MB/sec) – up to 590 TB/hr
SDLT 600 (2,048 drives, 36 MB/sec) – 265 TB/hr
|
| Audit time: |
<60 min
|
<60 min
|
| Average cell to
drive time: |
5 sec
|
5 sec
|
| Capacity, native
(uncompressed): |
T9840B (1,448
carts, 20 GB/cart) – 29 TB
T9840C (1,448 carts, 40 GB/cart) – 58 TB
T9940B (1,448 carts, 200 GB/cart) – 290 TB
LTO Gen 2 (1,448 carts, 200 GB/cart) – 290 TB
LTO Gen 3 (1,448 carts, 400 GB/cart) – 579 TB
SDLT 600 (1,448 carts, 300 GB/cart) – 434 TB
|
T9840B (300,000
carts, 20 GB/cart) – 6 PB
T9840C (300,000 carts, 40 GB/cart) – 12 PB
T9940B (300,000 carts, 200 GB/cart) – 60 PB
LTO Gen 2 (300,000 carts, 200 GB/cart) – 60 PB
LTO Gen 3 (300,000 carts, 400 GB/cart) – 120 PB
SDLT 600 (300,000 carts, 300 GB/cart) – 90 PB
|
| Number of
cartridge slots: |
Starts at 1,448
carts customer-usable slots
|
300,000
customer-usable slots
|
| Number of tape
drives / types: |
Up to 64 drives
of any combination of supported drives, including:
T9840 ESCON, Fibre Channel and FICON, T9940 ESCON, Fibre Channel and FICON,
LTO Ultrium Generation Fibre Channel, SDLT Fibre Channel
|
Up to 2,048
drives of any combination of supported drives, including:
T9840 ESCON, Fibre Channel and FICON, T9940 ESCON, Fibre Channel and FICON,
LTO Ultrium Generation Fibre Channel, SDLT Fibre Channel
|
| Cartridge access
port (CAP): |
Standard 39
cartridge slot CAP, optional 39 additional slots (78 total)
|
Up to 2,496
cartridge slots
|
| Mean exchanges /
swaps between failure (MEBF/MSBF): |
2,000,000
|
2,000,000
|
| Non-disruptive
serviceability: |
Standard N+1
power for drives, robotics and library electronics that can be replaced
while the library is operating.
|
Standard N+1
power for drives, robotics and library electronics that can be replaced
while the library is operating.
|
| Supported host
platforms: |
All major
operating systems
|
All major
operating systems
|
| Robotics control
interfaces: |
TCP/IP (IEEE
802.3, 100 baseT, half-duplex)
|
TCP/IP (IEEE
802.3, 100 baseT, half-duplex)
|
| Any Cartridge Any
Slot™ technology: |
Both minimum and
maximum configurations support full mixed media, any cartridge can be placed
in any cell, no required partitions
|
Both minimum and
maximum configurations support full mixed media, any cartridge can be placed
in any cell, no required partitions
|
| Digital vision
system: |
Unique digital
vision camera system performs continuous calibration and reads bar codes
|
Unique digital
vision camera system performs continuous calibration and reads bar codes
|
| Operator panel: |
Standard
web-accessible monitoring and control
|
Standard
web-accessible monitoring and control
|
| Automatic clean: |
Additional
dedicated cleaning cartridge slots are included for tape drive cleaning for
multiple drive types by library or software command
|
Additional
dedicated cleaning cartridge slots are included for tape drive cleaning for
multiple drive types by library or software command
|
| Automatic self
discovery: |
Auto-discovery
and auto-configuration for all drive, media types, slots and CAP
|
Auto-discovery
and auto-configuration for all drive, media types, slots and CAP
|
| Continuous
automation calibration: |
No periodic
maintenance or alignment required
|
No periodic
maintenance or alignment required
|
| Height: |
93.15 in (236.6
cm)
|
93.15 in (236.6
cm)
|
| Depth: |
109 in (276.9 cm)
|
296.5 in (753 cm)
|
| Width: |
67.25 in (170.8
cm)
|
2,338 in (5,938
cm)
|
| Weight: |
6,250 lb (2,835
kg)
|
492K lb (223mg)
|
| Temperature
(operating): |
+60° to +90° F
(+16° to +32° C)
|
+60° to +90° F
(+16° to +32° C)
|
| Temperature
(non-operating): |
+40° to +90° F
(+4° to +32° C)
|
+40° to +90° F
(+4° to +32° C)
|
| Relative humidity
(operating): |
20%-80%
|
20%-80%
|
| Relative humidity
(non-operating): |
20%-80%
|
20%-80%
|
| Voltage: |
Choice of 220–240
VAC @ 50–60 Hz single phase or three phase (Delta, Wye or SUVA). Optional
redundant inputs of any of the above.
|
Choice of 220–240
VAC @ 50–60 Hz single phase or three phase (Delta, Wye or SUVA). Optional
redundant inputs of any of the above.
|
| Power
consumption/dissipation: |
varies by
configuration
|
varies by
configuration
|
| Drives: |
Drive power
consumption varies. Refer to individual drive specifications
|
Drive power
consumption varies. Refer to individual drive specifications
|
| Safety: |
UL listed to UL
60950 (latest edition); CSA standard CAN/CSA-C22.2, no. 60950 (latest
edition); IEC Compliance EN60950, TUV compliance EN60950 (latest edition)
|
UL listed to UL
60950 (latest edition); CSA standard CAN/CSA-C22.2, no. 60950 (latest
edition); IEC Compliance EN60950, TUV compliance EN60950 (latest edition)
|
| Emissions: |
FCC Title 47,
Part 15, Subpart B, Class A; VCCI Class A (C1SPR22); European Union CE
emissions standards 89/336; AS/NZS 3548; Canada ICES-003, Taiwan (CNS13438)
|
FCC Title 47,
Part 15, Subpart B, Class A; VCCI Class A (C1SPR22); European Union CE
emissions standards 89/336; AS/NZS 3548; Canada ICES-003, Taiwan (CNS13438)
|
| Immunity: |
European Union CE
immunity standards (CISPR24/EN55024)
|
European Union CE
immunity standards (CISPR24/EN55024) |