| Throughput per
hour, native (uncompressed): |
LTO 2 (18 drives;
30-35 MB/sec) - over 2 TB/hr
LTO 3 (18 drives; 68-80 MB/sec) - over 5 TB/hr
SDLT 320 (18 drives; 16 MB/sec) – over 1 TB/hr
SDLT 600 (18 drives; 36 MB/sec) – over 2 TB/hr
|
| Capacity, native
(uncompressed): |
(maximum
configuration 575 cartridges) (mixed media - maximum configuration 494
cartridges)
LTO 2 (200 GB/cart) - 115 TB
LTO 3 (400 GB/cart) - 230 TB
SDLT 320 (160 GB/cart) - 79 TB
SDLT 600 (300 GB/cart) - 148 TB
|
| Number of
cartridge slots: |
30-575 slots
24-494 slots mixed media
Base module: 30-50 LTO cartridge slots, 24-42 slots mixed media
Drive expansion module: 90 additional slots, 77 additional slots mixed media
(without CAP)
Cartridge expansion module: 120 additional LTO cartridge slots, 113
additional slots mixed media (without CAP)
|
| Number of tape
drives / types: |
1-18 LTO 2/3 or
SDLT 320/600
|
| Cartridge access
port (CAP)*: |
Base module,
5-cartridge capacity (LTO only), 4-cartridge capacity mixed media
Drive expansion module, 10-cartridge capacity, 8-cartridge capacity mixed
media
Cartridge expansion module, 10-cartridge capacity, 8-cartridge capacity
mixed media
*CAP slots can be configured as data cartridge slots
|
| Mean exchanges /
swaps between failure (MEBF/MSBF): |
2,000,000
|
| Mean time to
repair (MTTR): |
<30 min
|
| Non-disruptive
serviceability: |
Hot-swappable
drives, Ethernet and serial ports for diagnostics and reporting. Redundant
hot-swappable power supplies with redundant fans.
|
| Supported host
platforms: |
UNIX, Windows NT,
Linux, Solaris
|
| Robotics control
interfaces: |
SCSI-3 Media
Changer command set, Low-Voltage Differential (LVD) – standard or 2-Gb
native Fibre Channel
|
| Any Cartridge Any
Slot™ technology: |
Simultaneous
non-partitioned support of multiple tape and media types
|
| Digital vision
system: |
Unique digital
vision camera system that performs continuous calibration and reads bar
codes
|
| Operator panel: |
Optional
user-friendly configuration and diagnostic controls, status display and
viewing window
|
| Automatic clean: |
Configurable
cleaning cartridge slot for tape drive cleaning by library or software
command
|
| Automatic self
discovery: |
Self-configuring
for cells, drives and cartridge access ports
|
| Continuous
automation calibration: |
No periodic
maintenance or alignment required
|
| Height: |
(Minimum
configuration)
14.00 in (35.6 cm)
|
| Depth: |
33.14 in (81.1
cm)
|
| Width: |
18.9 in (48.0 cm)
|
| Unit height: |
8u**
|
| Weight: |
76.4 lb (34.56
kg)
|
| Height: |
14.0 in (35.6 cm)
|
| Depth: |
33.14 in (81.1
cm)
|
| Width: |
18.9 in (48.0 cm)
|
| Unit height: |
8u**
|
| Weight: |
59.0 lb (26.9 kg)
|
| Height: |
14.0 in (35.6 cm)
|
| Depth: |
31.62 in (80.3
cm)
|
| Width: |
18.9 in (48.0 cm)
|
| Unit height: |
8u**
|
| Weight: |
44.2 lb (20.1 kg)
|
| Temperature
(operating): |
+50° to + 104° F
(+10° to 40° C)
|
| Temperature
(non-operating): |
+50° to + 104° F
(+10° to 40° C )
|
| Relative humidity
(operating): |
20%–80%
|
| Relative humidity
(non-operating): |
10%–95%
|
| Voltage: |
100–127 VAC,
200–240 VAC @ 50–60 Hz single phase (auto-ranging)
|
| Library
(operating maximum continuous - not peak): |
1.42 A @ 120 V,
0.75 A @ 240 V, 614 BTU/hr
|
| Drives: |
Drive power
consumption varies. Refer to individual drive specifications
|
| Electromagnetic
compliance: |
(Minimum
configuration)
14.00 in (35.6 cm)
|
| Safety: |
33.14 in (81.1
cm) |