Sun NAS
Sun Storage 7410 Unified Storage System
The Sun Storage 7410 Unified Storage System
scales up to 576 TB, providing maximum flexibility and performance. With its
extreme scalability, ease of use, and GUI-based DTrace Analytics, the Sun
Storage 7410 simplifies storage management and is your best price/performance
value. Plus, its hybrid storage architecture reduces energy consumption for
greater efficiency.
- Easy-to-use DTrace Analytics increase
production uptime
- Scales up to half a petabyte
- High-availability Cluster option protects
against downtime
- Flash Hybrid Storage Pool improves response
times
- Scales throughput, performance, and capacity
to meet application needs
- Enterprise data services with no additional
licensing fees
- Bulk unified storage
- HPC
- Web 2.0
- Server virtualization
- Database/BIDW
- Backup
Request Information
Simplifies Your Storage
Data management made easy
- Based on open source software and
industry-standard components
- Radically simplifies storage management
for less
- Installs in minutes without training
- Simple to configure and optimize
- Easy-to-use graphical tools provide
real-time visibility
- Comprehensive self-healing
Flash Hybrid Storage Pool
Optimized storage pool
Solaris ZFS, which comes with the Sun Storage
7410, uses a virtual storage pool to seamlessly optimize access to the
different media types, including SSDs, improving efficiencies and increasing
application performance.
SSD and SATA drives increase performance
The Sun Storage 7410 delivers up to twice the
performance at half the cost of traditional storage solutions, enabling you
to increase productivity without paying the price. In fact, it’s the only
storage system with hybrid pools, which increase performance and throughput
and shatter the I/O bottlenecks.
Increase application response times
The Sun Storage 7410’s hybrid architecture
combines Read- and Write-optimized Flash Accelerators with 7200 RPM SATA II
drives. This makes the 7410 ideal for organizations that require high-volume
throughput for write operations, and results in higher energy efficiency.
SSDs increase performance
SSDs dramatically increase performance while
cutting power consumption by up to 80% compared to spinning disks. Just what
you need to reduce space and energy costs and increase utilization and
scalability. Plus, the Sun Storage 7410 also utilizes 4000 RPM SATA II
drives for energy efficiency.
The flexibility to meet your changing needs
The Sun Storage 7410 provides you with the
highest-density server/storage solution available anywhere. Unlike
traditional storage architectures, the Sun Storage 7410 is highly adaptable
to changing business needs. The system not only scales up to 576 TB of
storage capacity in an 8U form factor, but also scales in multiple
dimensions, including I/O throughput, processor performance, and total
capacity.
For example, you can increase disk
performance by adding SSDs. As your application requirements change, you can
increase computational power by adding more CPUs and cache and expand total
capacity by adding enterprise-class SATA drive expansion units.
Cost-Effective
Easy on your budget
Flat or declining budgets are a fact of life
in today’s IT environments. But so are growing storage demands. The Sun
Storage 7410 can save you up to 75% when compared to the competition, while
still delivering twice the performance.
Eco-efficient
The Sun Storage 7410 helps you lower costs by
lowering energy consumption and offering higher storage density, which
reduces space requirements.
No additional software licenses
Unlike other vendors, who charge license fees
for protocols and data services, Sun includes features like CIFS, NFS,
replication, and snapshot restore with the Sun Open Storage Manager that
comes with the system. No additional licenses are required.
Reduced Risk
Solaris ZFS increases availability
The Sun Storage 7000 file system, ZFS, is a
transaction-based file system that only performs copy-on-write operation to
protect existing data, and provides RAID-Z DP to maximize data availability
Data integrity features keep you up and running
Checksum protection for data and metadata as
well as a self-healing mechanism to correct any potential data corruption
are included in the data integrity features.
Two-node cluster ensures availability
The Sun Storage 7410 supports a two-node
cluster configuration which has no single point of failure, reducing the
risk of downtime and ensuring that your business stays up and running.
Request Information
|
Architecture
|
| Configuration |
Single Controller or Dual
Controller (High Availability Cluster) |
|
| Processor |
Up to Four Quad-Core AMD
Opteron, per controller |
|
| Main Memory |
Up to 128 GB, per controller
|
|
| Read Flash Accelerator (Cache,
SSD) |
Up to 600GB (6 x 100GB Read
Flash Accelerator), per controller |
|
Standard and Optional Interfaces
|
| Integrated Network
|
Four 10/100/1000 Base-T
Ethernet ports, per controller |
|
| Expansion Bus |
Six internal MD2 Low Profile
PCIe slots, per controller |
|
| Optional Network Connectivity
|
- Dual GigE UTP
- Dual GigE MMF
- Quad GigE UTP
- Dual 10 GigE Fiber XFP (requires fiber
transceiver)
|
|
| Optional Tape Backup HBA
|
- Enterprise 4Gb FC HBA
- Dual channel
- Dual Channel Ultra320 SCSI HBA
|
|
Mass Storage
|
| Maximum Raw Capacity
|
Up to 288 TB (576 TB with free
software upgrade) |
|
| Disk Drives |
1 TB 7200 rpm SATA Disks
|
|
| Write Flash Accelerator (SSD)
|
Optional 18 GB Write Flash
Accelerators for write-oriented applications |
|
Software
|
| File System |
ZFS |
|
| Capacity |
128-bit capacity |
|
| File Level Protocol
|
NFS, CIFS, HTTP, WebDAV, FTP
|
|
| Block Level Protocol
|
ISCSI |
|
| Data Compression |
4 Levels of data compression
available |
|
| Replication |
1:N, N:1, manual, scheduled,
continuous |
|
| Thin Provisioning |
For Filesystems and iSCSI LUNs
|
|
| Flash (SSD) Device Support
|
- ZFS Log Devices (Write-optimized SSD)
- ZFS ARCL2 Devices (Read-optimized SSD)
|
|
| Administration |
Web (AJAX-based UI over
HTTPS), CLI |
|
| Monitoring |
- Storage DTrace Analytics (for system
performance tuning and debugging)
- Dashboard monitoring (for key system
performance metrics)
|
|
| Automated Serviceability
|
"Phone-home" through HTTPS
|
|
| RAID |
Striping, Mirroring, RAID-Z,
DP (RAID 5, 6) |
|
| ZFS Snapshots |
Virtually unlimited (depends
on system capacity) |
|
| ZFS Clones |
Virtually unlimited (depends
on system capacity) |
|
| ZFS Volumes |
Virtually unlimited (depends
on system capacity) |
|
| Virus Protection |
ICAP-based Virus scanning
utility (requires external virus scan engine) |
|
| Backup Protocol |
NDMP v3/v4 |
|
| No Single Point of Failure
|
- Multipath I/O for JBOD cabling
- Remote Replication for disaster recovery
- High-availability 2-node Cluster
(active-active, active-passive)
|
|
| Self-healing |
Predictive, Self-Healing
|
|
| Networking |
- IPV4, IPV6, Static or DHCP
- IP Multi-Pathing groups of addresses
- IEEE 802.3AD LACP
- IEEE 802.1Q VLANs
|
|
| Remote Management |
SNMP v2/v3 |
|
| CLI Scripting |
CLI syntax or by XML-RPC from
PERL, Python, Java, etc. |
|
| Remote Power |
Supported through IPMI-over-LAN
|
|
| Administration Security
|
Role-Based Access Control (RBAC)
|
|
| Auditing |
Access Logging |
|
| Directory Services
|
NIS, AD, LDAP |
|
| Data Security |
Checksum data and metadata
|
|
| Network Services |
NTP, DHCP, SMTP |
|
Storage Controller
|
| Power Supplies |
Dual redundant, hot -swappable
power supply |
|
| UL Maximum (AC Input)
|
8.2 Amps RMS at 100 VAC
|
|
| Power Supply Rating (DC
output) |
650 W |
|
| AC Power |
90–264 V AC (47–63 Hz)
|
|
| Operating Temperature/Humidity
(single, non-rack system) |
5 ºC to 35 ºC (41 ºF to 95
ºF), 10% to 90% relative humidity, non-condensing |
|
| Nonoperating
Temperature/Humidity (single, non-rack system) |
-40 ºC to 70 ºC (-40 ºF to 158
ºF), up to 93% relative humidity, non-condensing |
|
| Altitude (operating) (single,
non-rack system) |
Up to 3,048 m, maximum ambient
temperature is derated by 1 degree C per 300 m above 900 m |
|
| Altitude (nonoperating)
(single, non-rack system) |
15kPa |
|
| LwAd (1B = 10dB) at Max
Ambient [1] |
7.7 B |
|
| LpAm Bystander at Max Ambient
[1] |
65.8 dB |
|
| Safety Regulations [2]
|
IEC 60950, UL/CSA 60950,
EN60950, CB Scheme with all country differences |
|
| RFI/EMI Regulations [2]
|
FCC CFR 47 Part 15 Class A, EN
55022 Class A, EN 61000-3-2, EN 61000-3-3, EN 300-386 |
|
| Immunity Regulations [2]
|
EN55024, EN300-386
|
|
| Safety Certifications
|
UL/cUL, UL DEMKO, CE, BSMI,
CCC, GOST-R, S-Mark |
|
| EMC Certifications
|
CE, FCC, VCCI, ICES, C-Tick,
MIC, CCC, GOST-R, BSMI Class A |
|
| Other Certifications
|
Complies with WEEE Directive
(2002/96/EC) and RoHS Directive (2002/95/EC) |
|
| Height |
87.85 mm (3.46 in.)
|
|
| Width |
425.5 mm (16.75 in.)
|
|
| Depth |
711.2 mm (28 in.) |
|
| Weight |
28.6 kg (63lb) |
|
Expansion Array
|
| Storage |
- Drive population: 24 3.5” hard disk drives
per tray
- Supported drive types: 1TB, 7200 rpm SATA
II
- Write Flash Accelerator (SSD): Optional 18
GB Write Flash Accelerators
|
|
| Reliability, Availability and
Serviceability |
RAS features
- Hot-swappable components
- Non-disruptive hot-swappable I/O modules
- Non-disruptive hot-swappable disk drives
- Dual hot-swappable, load-sharing power
supplies/cooling modules
|
|
| Dimensions |
Height x width x depth:
6.88 in. x 17.52 in. x 24.02 in. (174.8 mm x 445.0 mm x 610.2 mm) including
SAS connector; including thumb screws, depth is 23.24 in. (590.3 mm)
Weight (maximum):
110.23 lb (50 kg) |
|
| Power |
Input voltage: 88 - 264 VAC
Input frequency: 47 – 63 Hz
Output power: 760 W
Power consumption: 110.62 VA, 100 W |
|
| Operating Environment
|
Heat output: 662 W (2123
BTU/hour)
Temperature: 35°F to 95°F (0°C to 35°C)
Humidity (non-condensing): 20% to 80% maximum
Altitude: 0 to 9843 feet (3000 meters)
Shock: 31G +/-5%, with pulse duration of 2.6 ms or less half-sine, bottom
side tested only
Vibration: 0.25 G (peak), 3 to 200 Hz sweep @ ½ octave per minute, bottom
side tested only |
|
| Regulations |
Electromagnetic emissions
standards
- FCC - Class A
- CE - Specific requirements in effect from
July 1, 2001
- VCCI - for Japan
- CCC - for China
- BSMI - for Taiwan/CNS/3438
- C-TICK - for Australia and New Zealand
Safety standards
- UL/CUL: for U.S. with Canada/UL60950-1
- TUV: for Germany/EN60950-1
- CB (by TUV): IEC60950-1
- BSMI: Taiwan/CNS14336
- CCC: for China
|