Sun Storage 7410 Unified Storage System

Front Top View: You get NFS, CIFS, HTTP, iSCSI, Replication, Compression, Snapshot/Clone and Restore, and DTrace Analytics, with no additional licensing fees

The Sun Storage 7410 Unified Storage System scales up to 576 TB, providing maximum flexibility and performance. With its extreme scalability, ease of use, and GUI-based DTrace Analytics, the Sun Storage 7410 simplifies storage management and is your best price/performance value. Plus, its hybrid storage architecture reduces energy consumption for greater efficiency.

  • Easy-to-use DTrace Analytics increase production uptime
  • Scales up to half a petabyte
  • High-availability Cluster option protects against downtime
  • Flash Hybrid Storage Pool improves response times
  • Scales throughput, performance, and capacity to meet application needs
  • Enterprise data services with no additional licensing fees
  • Bulk unified storage
  • HPC
  • Web 2.0
  • Server virtualization
  • Database/BIDW
  • Backup

Request Information

Simplifies Your Storage

Data management made easy
  • Based on open source software and industry-standard components
  • Radically simplifies storage management for less
  • Installs in minutes without training
  • Simple to configure and optimize
  • Easy-to-use graphical tools provide real-time visibility
  • Comprehensive self-healing

Flash Hybrid Storage Pool

Optimized storage pool

Solaris ZFS, which comes with the Sun Storage 7410, uses a virtual storage pool to seamlessly optimize access to the different media types, including SSDs, improving efficiencies and increasing application performance.

SSD and SATA drives increase performance

The Sun Storage 7410 delivers up to twice the performance at half the cost of traditional storage solutions, enabling you to increase productivity without paying the price. In fact, it’s the only storage system with hybrid pools, which increase performance and throughput and shatter the I/O bottlenecks.

Increase application response times

The Sun Storage 7410’s hybrid architecture combines Read- and Write-optimized Flash Accelerators with 7200 RPM SATA II drives. This makes the 7410 ideal for organizations that require high-volume throughput for write operations, and results in higher energy efficiency.

SSDs increase performance

SSDs dramatically increase performance while cutting power consumption by up to 80% compared to spinning disks. Just what you need to reduce space and energy costs and increase utilization and scalability. Plus, the Sun Storage 7410 also utilizes 4000 RPM SATA II drives for energy efficiency.

The flexibility to meet your changing needs

The Sun Storage 7410 provides you with the highest-density server/storage solution available anywhere. Unlike traditional storage architectures, the Sun Storage 7410 is highly adaptable to changing business needs. The system not only scales up to 576 TB of storage capacity in an 8U form factor, but also scales in multiple dimensions, including I/O throughput, processor performance, and total capacity.

For example, you can increase disk performance by adding SSDs. As your application requirements change, you can increase computational power by adding more CPUs and cache and expand total capacity by adding enterprise-class SATA drive expansion units.


Cost-Effective

Easy on your budget

Flat or declining budgets are a fact of life in today’s IT environments. But so are growing storage demands. The Sun Storage 7410 can save you up to 75% when compared to the competition, while still delivering twice the performance.

Eco-efficient

The Sun Storage 7410 helps you lower costs by lowering energy consumption and offering higher storage density, which reduces space requirements.

No additional software licenses

Unlike other vendors, who charge license fees for protocols and data services, Sun includes features like CIFS, NFS, replication, and snapshot restore with the Sun Open Storage Manager that comes with the system. No additional licenses are required.


Reduced Risk

Solaris ZFS increases availability

The Sun Storage 7000 file system, ZFS, is a transaction-based file system that only performs copy-on-write operation to protect existing data, and provides RAID-Z DP to maximize data availability

Data integrity features keep you up and running

Checksum protection for data and metadata as well as a self-healing mechanism to correct any potential data corruption are included in the data integrity features.

Two-node cluster ensures availability

The Sun Storage 7410 supports a two-node cluster configuration which has no single point of failure, reducing the risk of downtime and ensuring that your business stays up and running.

Request Information

 

Architecture
Configuration Single Controller or Dual Controller (High Availability Cluster)

Processor Up to Four Quad-Core AMD Opteron, per controller

Main Memory Up to 128 GB, per controller

Read Flash Accelerator (Cache, SSD) Up to 600GB (6 x 100GB Read Flash Accelerator), per controller
Standard and Optional Interfaces
Integrated Network Four 10/100/1000 Base-T Ethernet ports, per controller

Expansion Bus Six internal MD2 Low Profile PCIe slots, per controller

Optional Network Connectivity
  • Dual GigE UTP
  • Dual GigE MMF
  • Quad GigE UTP
  • Dual 10 GigE Fiber XFP (requires fiber transceiver)

Optional Tape Backup HBA
  • Enterprise 4Gb FC HBA
  • Dual channel
  • Dual Channel Ultra320 SCSI HBA
Mass Storage
Maximum Raw Capacity Up to 288 TB (576 TB with free software upgrade)

Disk Drives 1 TB 7200 rpm SATA Disks

Write Flash Accelerator (SSD) Optional 18 GB Write Flash Accelerators for write-oriented applications
Software
File System ZFS

Capacity 128-bit capacity

File Level Protocol NFS, CIFS, HTTP, WebDAV, FTP

Block Level Protocol ISCSI

Data Compression 4 Levels of data compression available

Replication 1:N, N:1, manual, scheduled, continuous

Thin Provisioning For Filesystems and iSCSI LUNs

Flash (SSD) Device Support
  • ZFS Log Devices (Write-optimized SSD)
  • ZFS ARCL2 Devices (Read-optimized SSD)

Administration Web (AJAX-based UI over HTTPS), CLI

Monitoring
  • Storage DTrace Analytics (for system performance tuning and debugging)
  • Dashboard monitoring (for key system performance metrics)

Automated Serviceability "Phone-home" through HTTPS

RAID Striping, Mirroring, RAID-Z, DP (RAID 5, 6)

ZFS Snapshots Virtually unlimited (depends on system capacity)

ZFS Clones Virtually unlimited (depends on system capacity)

ZFS Volumes Virtually unlimited (depends on system capacity)

Virus Protection ICAP-based Virus scanning utility (requires external virus scan engine)

Backup Protocol NDMP v3/v4

No Single Point of Failure
  • Multipath I/O for JBOD cabling
  • Remote Replication for disaster recovery
  • High-availability 2-node Cluster (active-active, active-passive)

Self-healing Predictive, Self-Healing

Networking
  • IPV4, IPV6, Static or DHCP
  • IP Multi-Pathing groups of addresses
  • IEEE 802.3AD LACP
  • IEEE 802.1Q VLANs

Remote Management SNMP v2/v3

CLI Scripting CLI syntax or by XML-RPC from PERL, Python, Java, etc.

Remote Power Supported through IPMI-over-LAN

Administration Security Role-Based Access Control (RBAC)

Auditing Access Logging

Directory Services NIS, AD, LDAP

Data Security Checksum data and metadata

Network Services NTP, DHCP, SMTP
Storage Controller
Power Supplies Dual redundant, hot -swappable power supply

UL Maximum (AC Input) 8.2 Amps RMS at 100 VAC

Power Supply Rating (DC output) 650 W

AC Power 90–264 V AC (47–63 Hz)

Operating Temperature/Humidity (single, non-rack system) 5 ºC to 35 ºC (41 ºF to 95 ºF), 10% to 90% relative humidity, non-condensing

Nonoperating Temperature/Humidity (single, non-rack system) -40 ºC to 70 ºC (-40 ºF to 158 ºF), up to 93% relative humidity, non-condensing

Altitude (operating) (single, non-rack system) Up to 3,048 m, maximum ambient temperature is derated by 1 degree C per 300 m above 900 m

Altitude (nonoperating) (single, non-rack system) 15kPa

LwAd (1B = 10dB) at Max Ambient [1] 7.7 B

LpAm Bystander at Max Ambient [1] 65.8 dB

Safety Regulations [2] IEC 60950, UL/CSA 60950, EN60950, CB Scheme with all country differences

RFI/EMI Regulations [2] FCC CFR 47 Part 15 Class A, EN 55022 Class A, EN 61000-3-2, EN 61000-3-3, EN 300-386

Immunity Regulations [2] EN55024, EN300-386

Safety Certifications UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark

EMC Certifications CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A

Other Certifications Complies with WEEE Directive (2002/96/EC) and RoHS Directive (2002/95/EC)

Height 87.85 mm (3.46 in.)

Width 425.5 mm (16.75 in.)

Depth 711.2 mm (28 in.)

Weight 28.6 kg (63lb)
Expansion Array
Storage
  • Drive population: 24 3.5” hard disk drives per tray
  • Supported drive types: 1TB, 7200 rpm SATA II
  • Write Flash Accelerator (SSD): Optional 18 GB Write Flash Accelerators

Reliability, Availability and Serviceability RAS features
  • Hot-swappable components
  • Non-disruptive hot-swappable I/O modules
  • Non-disruptive hot-swappable disk drives
  • Dual hot-swappable, load-sharing power supplies/cooling modules

Dimensions Height x width x depth:
6.88 in. x 17.52 in. x 24.02 in. (174.8 mm x 445.0 mm x 610.2 mm) including SAS connector; including thumb screws, depth is 23.24 in. (590.3 mm)

Weight (maximum):
110.23 lb (50 kg)

Power Input voltage: 88 - 264 VAC
Input frequency: 47 – 63 Hz
Output power: 760 W
Power consumption: 110.62 VA, 100 W

Operating Environment Heat output: 662 W (2123 BTU/hour)
Temperature: 35°F to 95°F (0°C to 35°C)
Humidity (non-condensing): 20% to 80% maximum
Altitude: 0 to 9843 feet (3000 meters)
Shock: 31G +/-5%, with pulse duration of 2.6 ms or less half-sine, bottom side tested only
Vibration: 0.25 G (peak), 3 to 200 Hz sweep @ ½ octave per minute, bottom side tested only

Regulations Electromagnetic emissions standards
  • FCC - Class A
  • CE - Specific requirements in effect from July 1, 2001
  • VCCI - for Japan
  • CCC - for China
  • BSMI - for Taiwan/CNS/3438
  • C-TICK - for Australia and New Zealand

Safety standards

  • UL/CUL: for U.S. with Canada/UL60950-1
  • TUV: for Germany/EN60950-1
  • CB (by TUV): IEC60950-1
  • BSMI: Taiwan/CNS14336
  • CCC: for China

Request Information

__________________________________________________________________________________________________________________________________

       

Home    How to reach us!    Request a Quote or Information    Site Map   News    Forms    Policies   Education  Search

Please contact us at 800-663-5523 or click here  for Pricing, Inventory or to Request additional information on any product .